1995 OPEN FORUM Abstracts
- Smoking Habits Of Respiratory Care Practitioners In Ohio, Indiana, And Kentucky
- Preliminary Evaluation Of A Community Quit & Win Smoking Cessation Program
- Respiratory Therapists Provide Smoking Cessation Counseling To Hospitalized Smokers
- Knowledge Levels Of Respiratory Care Practitioners Regarding Nicotine Intervention In The Hospital Setting
- Asthma Care Education In Sports (Aces)
- Nicotine Intervention In The Curricula Of Respiratory Care Programs
- Effect Of Education On Inappropriate Arterial Blood Gas Acquisition In A Surgical Icu
- Collaborative Teaching Lab Reduces Incidence Of Auto-Peep:
- A Simple Model For Teaching The Variables Effecting Fdo2 And Fio2 With Common Oxygen Delivery Devices
- Effect Of Multi-Skilled Respiratory Care Practitioners On A Department Of Emergency Medicine
- California Management Survey Report On The Associate Degree Entry Level Practitioner
- Cognitive Levels And Frequency Of Distribution Of The Learning Objectives In Three Rc Textbooks
- Comparison On The Use Of The Modified Nedelsky's Procedure Performed By Rc Educators And Practitioners
- Traditional Versus Non-Traditional Methods Of Short Term Positive Pressure Ventilation: A Comparison Study
- Bipaptrach: A Novel Form Of Augmenting Ventilation
- Effects Of Volume Control (Vc) Versus Pressure Ventilation On Patients With Hypoxemic Respiratory Failure
- Pressure Controlled Inverse Ratio Ventilation (Pc-Irv) Is Ineffective Early In Adult Respiratory Distress Syndrome (Ards) Induced By Oleic Acid
- High-Frequency Oscillatory Ventilation In Pediatrics; A Review Of Application And Management Practice
- Improved Oxygenation In Rds With Early Hfov Compared To Cv: The Provo Multicenter Controlled Clinical Trial
- Adult High Frequency In Ards; A Review Of Two Cases
- Cardiac Status In A Group Of Long Term Ventilated Persons Suffering From Duchennes Muscular Dystrophy(Dmd)
- Nasal Assist Control Ventilation In The Postoperative Care Of Children With Congenital Heart Disease
- Inaccurate Static Inspiratory Pressures In Mechanically Ventilated Patients With Acute Lung Injury
- Pressure Regulated Volume Control In Pediatrics: A Case Study
- Continuous Negative Pressure Vs. Nasopharyngeal Cpap In Rsv, A Case Study
- Negative Pressure Ventilation In Rsv: A Case Summary
- Effect Of Clinical Guidelines In Reducing Unnecessary Respiratory Care In Non-Icu Patients
- A Survey Of Blood Gas Usage In An Urban Teaching Hospital Mricu: Implications For Reducing Utilization Of Resources
- Improving The Utilization Of Cpt In A Pediatric Population
- Oxygen Therapy Practice Patterns For Non-Icu Patients Indicates The Need For Tools To Standardize Oxygen Therapy Administration
- A Clinical Trial Of Computerized Oxygen Therapy Protocol For Non-Icu Patients
- Oxygen Utilization Protocol Project: Results Of Pilot Study
- Pediatric Oxygen (O2) Weaning Protocol: Successful Implementation And Cost Savings
- The Effect Of Rcp Determination Of Device, Dose, Frequency And Patient Self Administration Of Medicated Aerosols
- Effectiveness Of A Protocol For Metered Dose Inhaler With Spacer Delivery Of Albuterol For Pediatric Patients Hospitalized With Acute Asthma
- Early Experience With An Appropriateness Guideline For Sampling Arterial Blood Gases In An Icu
- Use Of A Therapist-Driven Bronchial Hygiene Protocol In Patients Undergoing Cardiac Surgery
- Respiratory Alkalosis Created By Heart Beat Triggering Of The Ventilator
- Success Predictors For Passy-Muir Speaking Valve Use In A Pediatric Population: A Method Evaluation
- Hepatization Of A Lung Lobe As A Cause Of Persistent Cough
- Intermittent Regular Treatment Of Moderate To Severe Asthma With Theophylline Is Beneficial
- The Clinical Effect Of Helium-Oxygen Mixtures On Gas Exchange In Patients With Obstructive Ventilatory Defects
- Adaptor Ap-2, A Coated Pit Protein Complex, Is Required For Alveolar Macrophage Phagocytosis
- Successful Independent Lung Ventilation In A One-Year Old
- Temperature Loss In Deadspace Exposed To Ambient
- Assessment Of Endotracheal Tube (Ett) Placement In Neonates Using A Fiberoptic Stylet
- Improved Versatility Using New Cuffed Tracheostomy Tubes In Children On Home Mechanical Ventilation
- The Effect Of External Nasal Dilation On Athletic Performnace
- Comparison Of Ear Vs. Finger Proees In Cystic Fibrosis (Cf)
- Case Management Approach To The Care Of Ventilator Dependent Patients In A Community Hospital
- Use Of A Registry & Respiratory Therapist-Driven Protocol For Non-Invasive Assisted Ventilation (Nav) In The Hospital Setting
- Comparing The Length Of Ventilation On Cabg Patients Pre/Post Weaning Pathway
- Optimizing Ventilator Care Using A Ventilator Management Team In A Pediatric Intensive Care Setting
- Favorable Patient Outcomes And Significant Savings For Patients Placed On Ventilator Protocols Post Open Heart Surgery - A One Year Study
- Post-Operative Respiratory Care Protocol For Lung Transplant Patients - Report Of A Method
- Trach Team: A Multidisciplinary Approach To Managing Tracheostomies In A University Teaching Hospital And Trauma Center
- Multidiscipline Approach To A Successful Cost Reduction Initiative: Changing From Disposable To Permanent Oximetry Sensors
- Staff Empowerment In A Bargaining Unit Environment Contributes To Reduction In Middle Management
- Pediatric Department Developed Method To Achieve Internal Redesign
- Pediatric Respiratory Driven Protocols: Appropriateness Of Therapy, Economic Savings And Patient Outcomes-T
- Length Of Mechanical Ventilation Following Surgery For Congenital Heart Disease
- Direct Measurement Via An Inline Pneumotach Is Necessary To Determine Effective Tidal Volume In Children
- The Prognostic Implications Of A Failed Weaning Attempt
- Predicting The Weaning Time In Post-Operative Cardiothoracic Surgery Patients
- Bicore: An Efficient, Cost-Effective, Non-Invasive Weaning Tool
- Preoperative And Perioperative Predictors Of Prolonged Intubation Time With Coronary Artery Bypass Graft Patients
- Validation Of Fio_2 Stability In The Puritan Bennett 7200ae Ventilator With The 7250 Metabolic Monitor
- In Vitro Validation Of The Puritan-Bennett 7250 Metabolic Monitor
- Comparison Of The Imposed Wob During Imv In Five Ventilators For Sub-Acute Care
- Measurement Of The Dynamic Rapid Shallow Breathing Index
- Estimation Of Energy Expenditure In Critically Ill Infants And Children Receiving Mechanical Ventilation In The Pediatric Intensive Care Unit
- Muscular Activity Contributes To The Increase In Oxygen Demand During Chest Physiotherapy
- Optimal Work Of Breathing With Negative Pressure Ventilation
- System Dead Space (Vsys) As A Quality Control Indicator For Helium Dilution Lung Volumes
- Determinations Of Ionized Calcium/Electrolytes In Blood Gas Syringes
- The Ph Of Solutions Used For Methacholine Challenge
- Evaluation Of Ten Brands Of Single-Patient Use Portable Peak Flow Meters (Ppfms)
- Evaluation Of The Nonin Finger Phantom As A Standard For Checking Pulse Oximetry Performance
- Oxygen Pulsing Devices: Effects Of Different Flow Profiles On Simulated Rest And Exercise Conditions
- Qualification Of Multiple Metabolic Systems For Use In The Pediatric Clinical Setting
- Does Sampling Rate Effect The Relative Agreement Of Petco2 Measured By Raman And Mass Spectrometry?
- Accuracy Comparison Of Bedside And Laboratory Blood Gas Analyzers
- Virtual Abg's Derived From Noninvasive Etco_2 And Spo_2 Data
- Capacity Of The Servo2 Oxygen Control System To Control For Set Fio2 And Feco2--
- A Subjective Scoring Tool For Assessing Reversible Airways Obstruction
- Airway Resistance And Lung Volumes Are Valuable Adjuncts To Spirometry For Assessing Reversible Of Airway Obstruction
- Lung Volume Stability During Postnatal Growth In Preterm Infants With Respiratory Distress Syndrome
- Neurorespiratory Drive, Respiratory Muscles Efforts And Mechanics Of Breathing In Patients Before And After Special Training Of Respiratory Muscles
- The Effect Of Actuation Interval On Dose Availability With Metered Dose Albuterol
- Effect Of Longterm Reservoir Use On Dose Availability With An Inhaled Corticosteroid
- Air Entrainment Properties Of Three Brands Of Mdi Spacer Systems
- Air Flow Resistance For Three Brands Of Mdi Spacer Systems
- Effect Of Multiple Mdi Actuations On Dose Availability From A Spacer
- Albuterol Administered By Metered Dose Inhaler With Holding Chamber Is More Effective Than Jet Nebulization In Treating Acute Asthma In Children
- Albuterol Aerosolized By Ultrasonic Nebulizer Is Less Effective Then Jet Nebulization For The Treatment Of Acute Asthma In Children
- Bronchodilator Therapy Through Airway For Patients With Mechanical Ventilation: A Comparison Of 3 Delivery Methods
- Characterization Of Liposome-Laden Aerosols Delivered By A Multiport Aerosol Chamber
- Pattern Of Deposition And Aerosol Particle Size In A Dry Vs Humidified Ventilator Circuit Using Metered Dose Inhaler And Spacer
- Determination Of Regional Ventilation In Mechanically Ventilated Patients: Usefulness Of ^{99m}Tc-Dtpa Aerosol
- Performance Evaluation Of The Heart Continuous Nebulizer
- Effect Of Inhaled Nitric Oxide Before, During, And After Cardiopulmonary Resuscitation
- Nitric Oxide (No) And Nitrogen Dioxide (No_2) Levels During Manual Ventilation
- Lab Evaluation Of Nitric Oxide Delivery Via Transport Ventilator
- Environmental Exposure Of Nitric Oxide/Nitrogen Dioxide In An Nicu During Simulated Mechanical Ventilation
- Nitric Oxide And The Measurement Of Metabolics With A Puritan-Bennett 7250 Metabolic Monitor
- Inhaled Nitric Oxide Improves Oxygenation But Worsens Lung Mechanics In Experimental Respiratory Distress Syndrome
- Methemoglobin Production Rates At Three Levels Of Hemoglobin Saturation And 80 Ppm Nitric Oxide
- Inspired Versus Tracheal [No]
- Air Transport Of A Ventilated Infant Requiring Nitric Oxide Therapy - Case Study
- Response Of Chemiluminescent Analyzers On The Measured Value Of Nitric Oxide (No)
- Evaluation Of Electrochemcial Nitric Oxide Analyzers
- Evaluation Of Four Inhaled Nitric Oxide Therapy Analyzers Using Known Concentrations Of Nitrogen Dioxide
- Evaluation Of Four Analyzers Used To Monitor Inhaled Nitric Oxide Therapy
- Evaluation Of Ten Adult Disposable Manual Resuscitators
- Evaluation Of Adult Disposable And Nondisposable Manual Resuscitation Bags
- Evaluation Of The Pulsair Oxygen Delivery System
- An Evaluation Of O2 Bleed Rates With Three Different Brands Of Blenders
- The Effects Of Varying Set Humidifier Temperature And Ventilator Flow Rate On The Relative Humidity Delivered By The Anamed Humiditube Heated Humidifier System
- The Effects Of Varying Set Humidifier Temperature And Ventilator Flow Rate On The Relative Humidity Delivered By The Fischer & Paykel Mr-730 Heated Humidifier
- Feasibility Of Recycling Pediatric Bicore Flow Sensors
- Accuracy Of Neonatal Tidal Volume Measurement Devices
- Bicore Cp-100 Analysis-Volume V/S Pressure Augmentation Max (Pam) On The Bear1000
- Siemens Servo 300 Performance Analysis
- Intelligent Co2 Monitoring
- Servo Lung Simulator
- Pressure Ventilation Despite Air Leaks: Quantitation Of Leak Volume And Maintenance Of Target Pressure
- Comparison Of Flutter^® To Positive Expiratory Pressure (Pep) Valves: A Laboratory Study
- Effect Of Changes In Altitude On The Operational Characteristics Of The Ambu Transcare Portable Ventilator
- Use Of A Relief Valve (Rv) To Eliminate The Rise In Peak Airway Pressure Seen During Tracheal Gas Insufflation With Pressure-Control Ventilation
- Continuous Vs. Expiratory Phase Tracheal Gas Insufflation During Pressure Control Ventilation: A Lung Model Study
- Continuous Vs. Expiratory Phase Tracheal Gas Insufflation During Volume Control Ventilation: A Lung Model Study
- Tracheal Gas Insufflation With A New Double Lumen Endotracheal Tube: A Comparison Of Continuous Vs. Expiratory Tgi During Pressure Control Ventilation
- Transtracheal Airway Insufflation Of Helium-Oxygen Mixtures Reduces Apparent Work Of Breathing
- Expiratory Tracheal Gas Insuflation (E-Tgi): A Prototype Device For Use With The Pb 7200ae Ventilator
- Tracheal Gas Insufflation In A Mechanically Ventilated Canine Model With Raised Intracranial Pressure
- Tracheal Gas Insufflation: A Bridge To High Frequency Ventilation
- Partial Liquid Ventilation: Histologic Differences Between High Frequency Ventilation And Conventional Ventilation
- Time Course Of Blood Gas And Lung Compliance Changes During Partial Liquid Ventilation In An Animal Model
- Quick-Fill Vs Slow-Fill With Partial Liquid Ventilation
- Pressure Volume Curves During Partial Liquid Ventilation
- A Prospective, Randomized Trial Of 7 Day Ventilator Circuit Changes Versus No Routine Circuit Changes For Patients Requiring Prolonged Mechanical Ventilation
- Impact Of Seven (7) Day Ventilator Circuit Changes On Rates Of Lower Respiratory Tract Infection (Lri) In A Pediatric Population. A Pilot Study
- Ventilator Associated Pneumonia (Vap) In A Subacute Setting With 7 Day Circuit Change
- Extending Ventilator Circuit Change Interval Beyond Two Days Reduces Likelihood Of Ventilator Associated Pneumonia (Vap)
- Movement Of Bacterial Contaminants Is Reduced In Heated Ventilator Circuits
- Open Disconnect Versus Closed In-Line Suctioning During Hfov
- Effect Of Ventilator Adjustments During Closed Inline Suctioning With Hfov
- Do Tape And Repeated Sterilization Affect The Accuracy Of Disposable Pulse Oximeter Probes?
- O_2 Operating Costs Of Resuscitation Bags In The Nicu And Picu
- Results Of Multiple Sequential Sputum Inductions On The Diagnosis Of Pneumocystis Pneumonia
- Comparison Of Wob, Rise Time, And Pressure Overshoot During Psv With Two Ventilators
- Effects Of Changes In Inspiratory Rise Time On Imposed Work Of Breathing In A Pediatric Animal Model
- Response Times Of Pediatric/Neonatal Pressure-Support Ventilators
- Evaluation Of Three Adult Pressure-Support Ventilator Response Times
- Flow Versus Pressure Triggering In Mechanically Ventilated Adult Patients
- The Effects Of Airway Leak On Tidal Volume During Pressure Or Flow Controlled Ventilation Of The Neonate: A Model Study
- Altering Flow Rate During Pressure Support Ventilation: Effects On Work Of Breathing And Respiratory Drive
- Effect Of Variations In Source Gas Pressure On Observed Flow Output Of Two Transport Ventilators
- Pressurization Rate Regulation May Reduce Inspiratory Effort During Pressure Support Ventilation (An 'in Vitro' Study)
- Predictive Equations For Determination Peak Airway Pressure
- Infant Ventilator Performance Varies With Lung Condition And Cycling Frequency
- Volume Accuracy Of The Siemens Servo 900c And Novametrix Ventrak When Delivering Helium-Oxygen Mixtures
- Resistance Increase In A Breathing Circuit Filter When Used In Conjunction With Continuous Nebulized Bronchodilation
- Dynamic Measurements Of Intrinsic Peep Do Not Represent The Lowest Intrinsic Peep
- Ability Of Bilevel Cpap Ventilators To Meet Inspiratory Demand: A Lung Model Study
You are here: RCJournal.com » Past OPEN FORUM Abstracts » 1995 Abstracts