The Science Journal of the American Association for Respiratory Care

2005 OPEN FORUM Abstracts

High Flow Nasal Cannula with Heliox for Post Extubation Respiratory Failure on an infant with Unrepaired Congenital Heart Disease.

Douglas Petsinger BS,RRT, Kevin Maher MD, Janet Simsic MD, Angel Cuadrado MD

INTRODUCTION: A 4.6 Kg 4 month old with transitional AV Canal, Cleft Mitral Valve, Mitral Stenosis, and resultant pulmonary artery hypertension (PAH), and gastro-esophegeal reflux (GER) was admitted to Children's Healthcare of Atlanta's cardiac intensive care unit (CICU) following a diagnostic cardiac catheterization. Previous surgical interventions included an end to end anastamosis of a coarctation, gastric tube, and a fundo plication. The cardiac catheterization data revealed a pulmonary vascular bed that was responsive to oxygen. The pulmonary vascular resistance decreased from 13.2 units to 3.8 units with application of 100% O2 during the procedure. The patient remained on O2 via a 2 LPM nasal cannula and was started on both IV Milrinone at 0.7 mcg/Kg/min and Sildenafil. Post cardiac catheterization day # 1, the patient developed bradycardia (sustained HR < 80 BPM) and desaturation (SpO2/SaO2 < 60%), the patient was intubated and mechanically ventilated.

CASE STUDY: On CICU day # 8, the patient was able to be supported on low levels of mechanical support. The pre extubation settings were PSV/CPAP 40%, +5 cm CPAP, +8 cm PSV, Vt (exh.) 4.5cc/Kg, and RR at 30 BPM.

Extubation Hour HR/RR BPM CVP mm/Hg FiO2/ Total Flow/ HeO2 Flow pH PvCO2 BE/ HCO3 SvO2 POC / SpO2 Glucose POC
0 109/32 13 PSV/ CPAP 7.41 56 +9/36 74%/ 96% 91
1 125/34 14 100%/ 2L / 0 7.29 76 +7/37 57%/ 93% 144
3 138/44 16 50%/ 10L / 0 7.28 73 +5/34 56%/ 92% 182
4 149/50 15 50%/ 13L / 0 7.33 71 +9/38 58%/ 94% 252
7 155/50 15 40%/ 10L/ 5L 7.36 64 +9/37 66%/ 96% 254
8 113/24 7 40%/ 10L/ 5L 7.42 54 +8/35 80%/ 99% 268
14 110/20 7 40%/ 10L/ 5L 7.40 59 +9/37 72%/ 99% 89
30 116/22 6 40%/ 8L/ 5L 7.38 57 +7/34 80%/ 96% 89

DISCUSSION: The patient's post extubation respiratory failure was due to CO2 clearance issues that resulted in an increase in WOB, HR, and patient stress exhibited by a rapid elevation in patient glucose levels. There also was an increase in PVR due to increasing respiratory acidosis as evidenced by an increase in CVP and dasaturation. There was some relief with the institution of HFNC via vapotherm Nasal Cannula System, but the patient still remained tachypenic and physiologically stressed. The addition of Heliox (HeO2) at an 80/20 mix enhanced CO2 clearance in combination with the positive pressure characteristics of the HFNC. The benefit of HeO2 is in the physical properties of the gas, specifically the density and the viscosity. These characteristics combined with the velocity of flow through the HFNC were able to improve the alveolar-pulmonary capillary interface and improve alveolar ventilation. The patient's CO2 clearance issues most likely were a result of long standing GER and a cardiac lesion that increase pulmonary blood flow creating peri-bronchial cuffing (a reversible physiologic mechanical obstruction, AKA cardiac asthma). With the interventions that promoted improving CO2 clearance the patient was able to relax due to ease of WOB and there was a steady physiological response to decreasing levels of stress.